A French door threshold is the strip at the bottom of the frame that seals the gap between inside and outside, and its height decides how easily you step through and how well the door keeps out water and draughts. For most UK homes the sensible target is a low threshold of no more than 15 mm overall, matched to a drained, sloping external landing. A composite French door ordered with the threshold specified at the start avoids the common mistake of discovering the wrong sill when the doors arrive.
This guide explains what the threshold does, what the UK rules say about height, which types exist, and what to check before you order or replace.
TL;DR
- A threshold seals the base of the door against draughts, moisture and noise and supports the stability of the whole door assembly.
- Under Approved Document M, an accessible threshold is level or no more than 15 mm in total height, with any upstand above 5 mm chamfered or rounded.
- A new principal entrance door must have a threshold no higher than the one it replaces. Level thresholds are a legal requirement in new-build housing, not in most renovations.
- The lower the threshold, the more the drainage and weatherproofing around it matter: check the landing slope and the drainage before you commit.
- Decide the threshold type when you choose the door, not after delivery.
Table of Contents
- What a French door threshold does
- How low can a French door threshold be?
- What the rules say in England and Wales
- Choosing the right threshold for exterior French doors
- Drainage, sealing and installation: where low thresholds go wrong
- Can you replace just the threshold?
- Security and a low threshold
- Choosing composite French doors with the threshold in mind
- Order and delivery: what to expect
- Checklist before you order
- FAQ
- Sources
What a French door threshold does
The threshold, sometimes called the sill or cill, sits across the bottom of the door opening. It forms the junction between the floor inside and the ground outside, and it gives the door leaves something to seal against. Manufacturers of door hardware describe it as the part that keeps out draughts, moisture and noise while adding to the stability and durability of the door.
On a pair of French doors the job is harder than on a single door. There are two leaves meeting in the middle, so water and air have a longer line to get through and the centre point, where the leaves meet the threshold, is the weak spot. A well-made threshold has a raised upstand or a sloped profile that sheds water outwards, a gasket or brush seal the leaf closes onto, and a thermal break in aluminium versions so the metal does not carry cold into the room.
You will see three broad types:
- Standard raised threshold: a taller sill, often 40 to 60 mm, with the best natural resistance to driving rain.
- Low threshold: a slim profile, typically around 15 to 25 mm, that reduces the step while still giving a defined water barrier.
- Level or flush threshold: the finished floor and the external landing sit at almost the same height. It looks the cleanest but needs the most careful drainage detailing.
The heights above are typical ranges you will meet when comparing products, not legal limits. The legal figures follow below.
How low can a French door threshold be?
In England, the reference point is Approved Document M, the government’s guidance on access to and use of buildings. It describes an accessible threshold as one that is level or, if it has to be raised, no more than 15 mm in total height. The same document says any upstand higher than 5 mm should be chamfered or rounded so it is less of a trip hazard and easier for a wheelchair or pushchair to cross.
The wording for non-domestic entrances goes further. Approved Document M Volume 2 asks for a threshold that is level or, where a raised one cannot be avoided, no more than 15 mm with a minimum number of upstands and slopes. It also says the route across the threshold should give weather protection and should not be a barrier or trip hazard. That matters if you manage rental or commercial property with French doors on an accessible route.
A worked example makes the figures easier to picture. Say your old French doors have a 40 mm sill and you want a gentler step. A 15 mm low threshold takes 25 mm off the step, roughly the thickness of two pound coins stacked ten high, which is enough to make a visible difference for a wheelchair, a walking frame or a pram. A true flush threshold removes the step altogether but asks more of the ground outside.

Does a low threshold always mean weaker weather protection?
Not if it is specified and drained properly, but there is a trade-off to understand. FENSA, the scheme under which installers self-certify window and door replacements, notes in its compliance guide that there is often a compromise between meeting access requirements and weatherproofing performance. Its advice is that occupants may have needs beyond the minimum in the regulations, so the right height is the lowest one that your site can drain properly.
In practice that means the threshold, the external landing and the drainage work together. A low threshold on a patio that slopes towards the house will let water in whatever the product.
What the rules say in England and Wales
The rules depend on whether the work is new-build or a replacement, and on the age of the existing door.
New-build housing. Architizer’s UK technical guide states that level thresholds are a legal requirement for new-build housing, so all external doors, French doors included, must provide a level entrance and exit. In renovations it says they are not a building regulations requirement, although some councils may require them as a planning condition. If your project involves an extension or conversion, check the planning conditions as well as the building control notice.
Replacing a principal entrance door. FENSA’s guide states that a replacement principal entrance door must have a new threshold no higher than the previous one. French doors are not always the principal entrance, but the principle is a good habit anyway: never make access worse than it was.
Older doors and exposure. The industry’s Good Practice Guide for installing replacement windows and doors, citing Part M, gives thresholds of no greater than 35 mm for protected doorways and low-exposure doors, and no greater than 50 mm in high-exposure locations, for doors that pre-date the 2004 requirements. Where a low threshold is impossible, a gap of up to 35 mm from the underside of the door leaf to the finished floor level is normally acceptable. The same guide suggests a clear opening width of at least 775 mm at a principal entrance.
What has changed recently. GOV.UK’s Approved Document M page was last updated in October 2024, with May 2024 amendments to Volume 2. Since April 2023 the Building Safety Regulator has had a duty to keep building standards under review. The threshold height figures quoted above have not changed, but it is worth checking the current version of the document, or asking your installer, before you start a project.
These figures apply in England. Wales, Scotland and Northern Ireland have their own building regulations, so check the local equivalent if you are outside England.
If you want a wider view of designing for access in a home, this practical guide to accessible design covers the principles that sit behind rules like the 15 mm limit.
Choosing the right threshold for exterior French doors
Start from the use of the doorway and the ground outside, then work back to the product.
1. Who needs to use the door?
If anyone in the household uses a wheelchair, walker or pram regularly, or you manage property where accessibility is expected, choose a low or level threshold and design the landing for it. If the doors open onto a sheltered garden room or a raised decking area, a slightly higher threshold is a legitimate choice with better rain resistance.
2. What is the floor like on each side?
Measure the finished floor height inside, including any new flooring that is about to go down. A tile or engineered board can add 10 to 20 mm, and a threshold fitted to the bare screed can end up sitting too low or too high against it. Then measure the external level. The step you have is the step the threshold has to deal with.
3. What is the door made of?
Architizer’s guide notes that most manufacturers state whether a door system is Part M compliant, but that the base frame of front and rear doors needs checking, timber ones especially, and that special aluminium thresholds may be needed for full accessibility. Material affects what profile is possible: aluminium sills can be slim and strong, while composite and uPVC frames typically use a sill profile built into the frame system. Read the product’s technical details for the threshold height rather than assuming.
4. How exposed is the doorway?
A door facing the prevailing wind with no porch or overhang needs a threshold with a taller upstand or a very well-drained landing. A sheltered, covered door can go lower with less risk.
Quick comparison
| Threshold type | Typical step | Best for | Watch for |
|---|---|---|---|
| Standard raised | 40 to 60 mm | Exposed doorways, older properties | Trip hazard, harder for wheelchairs and prams |
| Low, up to 15 mm | 15 mm or less | Most homes, accessible routes | Needs a sloping, drained landing |
| Level or flush | Near zero | New-builds, step-free access | Needs a drainage channel and careful detailing |
The step ranges are typical market ranges for comparison; the 15 mm figure is the Approved Document M limit.
Drainage, sealing and installation: where low thresholds go wrong
Most problems with a low threshold are not the threshold itself. They are what is outside it.
Architizer’s guide gives the detail for a level threshold: the threshold including the frame should be no more than 15 mm overall, the external landing should fall at a ratio of 1:40 to 1:60 so all water runs away from the doorway in one direction, and a drainage channel should sit between the landing and the threshold, discharging to a drain or soakaway. In plain terms, for every 40 to 60 cm of paving the ground should drop 1 cm. On a 1.2 m deep patio that is a fall of 2 to 3 cm.

The same guide explains that a drain can sit flush with the level floor or be hidden under finishes, and that damp proof membranes should be draped up the door frame at the threshold with the damp proof course at least 150 mm above ground level on either side. If your landing is a new patio, give the paving contractor those figures before they lay anything.
A sensible installation sequence:
- Check the opening. The sill area should be solid, level and dry. Rot or crumbling brickwork must be repaired first.
- Set the threshold level. Pack and fix it so it does not rock. A threshold that moves breaks its own seal.
- Seal behind and beneath. Use the sealing method the manufacturer specifies for the sill and the damp proof course.
- Fit the doors and adjust. The leaves should compress the seals evenly along the whole width, including at the centre where they meet.
- Finish the landing. Lay external paving to the fall and keep the drain clear.
A quick test after fitting: close the doors on a strip of paper at several points along the threshold. Where it slides out freely, the seal is not tight enough and needs adjusting.
Can you replace just the threshold?
Sometimes, but it is rarely a small job. The threshold is built into the door frame system, so replacing it can mean lifting the door leaves off, removing the old sill, repairing whatever is underneath and re-sealing the base. If the reason is a worn seal or a bent cill cap on an otherwise sound frame, a like-for-like replacement may be possible. If the aim is to reduce the step, a new threshold also changes the relationship to the floors and the landing, and the doors usually need to be reset or replaced to match.
The reasons to consider replacing the whole door set include:
- the frame has dropped, so the leaves no longer meet the threshold evenly;
- you are changing the internal floor level;
- the door is past its useful life for security or insulation;
- you want a lower threshold that the existing frame cannot take.
Our guide to French door replacement: options, costs and what to check covers how to weigh a repair against a new set.
Security and a low threshold
A slimmer threshold does not have to mean weaker security. The locking is what protects the doorway, and French doors have two leaves, so a multi-point lock that secures along the height of the leaves matters more than the sill. When you compare products, look at the locking system and the frame construction alongside the threshold height.
We build our approach to French doors around security and a smooth ordering process. Our range includes composite French doors with high-security locking mechanisms, and customers can choose supply-only or fully fitted. When someone asks us about thresholds, our advice is to settle the height, the landing and the door together, because they affect each other. A threshold chosen first and a door chosen second is how mismatches happen. We would rather you spend ten minutes measuring the floors inside and outside before ordering than discover a step you did not plan for when the doors arrive.
Tell us what the doorway has to do, whether it is a step-free route, a sheltered garden room or an exposed back door, and the choice of door follows from that.
the author
Choosing composite French doors with the threshold in mind
Composite French doors suit homeowners, landlords and property managers who want a durable, low-maintenance pair of doors with strong locking. Our composite French doors collection includes designs such as the 48mm Mowbray and the 48mm Kent. Each product page gives the specification, so you can compare threshold details alongside style and colour.
If your opening is wide and you want a lot of glazing, aluminium is the other route. Our aluminium bifold doors range from £1,756 to £3,072, aluminium sliding patio doors range from £1,077 to £2,754, and aluminium single access doors start from £550. Prices are those published on our site and depend on size and configuration.
Order and delivery: what to expect
Choose supply-only if you have a builder or fitter lined up, or fully fitted if you want one order to cover everything. Supply-only orders are delivered in 10 working days, and fitted options take 3 to 4 weeks. Measure the opening, note the internal and external floor levels, and decide the threshold height before you order.
Looking to replace a tired pair of French doors with something secure and well finished? Browse our composite French doors, or see the full range at Value Doors.
Checklist before you order
- Measure the opening width and height, and the finished floor heights inside and outside.
- Decide whether the doorway needs to be step-free or low-step.
- Check the landing slope (1:40 to 1:60 away from the door) and where the water will go.
- Confirm the threshold height in the product specification and whether the product is described as Part M compliant.
- Check the damp proof course sits at least 150 mm above ground level.
- Decide between supply-only and fully fitted before ordering.
- Ask your installer for the FENSA certificate once the work is complete, as replacement doors in England should be signed off.
FAQ
What is the slope of a door threshold?
The threshold itself should be level or have gently chamfered or rounded edges on any upstand above 5 mm. The slope matters outside: the landing should fall at 1:40 to 1:60 away from the door so water drains away from the doorway.
Do French doors need a low threshold?
Only in specific cases. Level thresholds are a requirement for new-build housing, but in renovations they are not a building regulation requirement, though a council may attach one as a planning condition. Many homeowners choose a low threshold anyway for comfort and ease of access.
What type of threshold do I need for an exterior door?
Choose according to exposure, access needs and the ground outside. A low threshold of up to 15 mm suits most homes with a drained, sloping landing, while a taller upstand suits a very exposed doorway. Check the product specification for the exact height.
How do I stop water coming under French doors?
Check three things: a threshold seal that compresses evenly, a landing that falls away from the door, and a drainage channel if the threshold is level. Keep drains clear of leaves and debris. A threshold seal that has worn or a frame that has dropped should be looked at by the fitter.
Sources
- Door thresholds, Gretsch-Unitas
- FENSA Guide to Compliance
- Approved Document M Volume 2, 2024 edition
- Technical Details: An Architect’s Guide To Level Thresholds, Architizer
- Good Practice Guide for the Installation of Replacement Windows and Doors
- Access to and use of buildings: Approved Document M, GOV.UK